THE ULTIMATE OVERVIEW TO ESTABLISHING YOUR IP PA SYSTEM SUCCESSFULLY

The Ultimate Overview to Establishing Your IP PA System Successfully

The Ultimate Overview to Establishing Your IP PA System Successfully

Blog Article

Network PA System for medium to large-scale projects



Introduction


The XC-9000 system is a completely digital network PA system based on the TCP/IP protocol. By leveraging the TCP/IP protocol, the system makes sure the efficient and appropriate transmission of all data packets. Not only can it use existing computer system networks, such as LANs or the Net, to send program signals, yet also it can also be deployed on a devoted broadcasting network.


A single-server system can support up to 3000 terminals and permits for server plunging. There are no restrictions on the concurrent broadcast networks, attaining real full electronic broadcasting.


System Qualities



Versatile PA System Style


The PA system style is basic, including solution monitoring software program, network microphones, network amplifiers, network speakers, and various other devices.All devices is attached by means of the TCP/IP intranet method, enabling adaptable setup and easy monitoring of the system, with cost-free control over broadcast web content, network gadgets, and regions via the network.


Ip Paging SystemSpon Communications
Comprehensive Audio Monitoring


The audio monitoring software includes integrated features for developing broadcast strategies, flexible zoning, and pre-scheduled broadcasts.It sustains 24-hour programming, permitting changing setups during throughout the day


Versatile Audio Source Assistance


The system supports numerous forms of audio resources for sending notifications like real-time speech and BGM playback. Audio resources can come from digital music applications, CD/DVD gamers, microphones, and so on. On top of that, the system gives diverse functions of sustaining various broadcasting functions such as set up broadcasting, zoned broadcasting, and emergency broadcasting.


Fire Alarm System System Combination


The system has a fire alarm function and can be incorporated into a smoke alarm system. When the alarm system main unit obtains the alarming signals, the cable television will certainly transmit the signal to tools, which triggers the XC-9000, sending out signals to audio speakers


Customers could pick to preset settings to activate full-area or zoned alarm systems in emergencies. The alarm system voices come in several types and can be modified catering to demands. Customers can transform language setups, upload and modify their audio resources according to precise demands, such as intruding alarm systems, fire alarm systems or air help alarm systems, and so on.


Emergency Alarm System Combination


The system has an emergency alarm feature and can be incorporated right into an emergency alarm system. When the alarm main device gets the disconcerting signals, the cable television will certainly send the signal to tools, which causes the XC-9000, sending signals to audio speakers


Customers can select to pre-programmed setups to trigger full-area or zoned alarm systems in emergencies. The alarm system voices can be found in numerous kinds and could be edited dealing with demands. Users can alter language settings, upload and edit their audio sources according to specific demands, such as intruding alarms, fire alarms or air help alarms, and so on.


Application Control for System Workflow


The system enables mobile application login and use, permitting individuals to start broadcasts and various other procedures to accredited terminals with the server software, making certain a hassle-free and structured experience.


Integrated SIP Compatibility


The system not only enables SIP phones to log in, yet additionally can be attached to third-party SIP server or IPPBX, which develops a totally incorporated and suitable communication system via seamless assimilation into existing systems.


Open up SDK


When huge job like clever park happens, the system provides an open SDK incorporated into third-party application systems - IP PA System


System Infrastructure



Key Functions


Arranged Playback


The system has the ability to automatically relay according to the set up tasks as long as individuals publish the audio documents for each amount of time of the day to the web server and create a playback schedule.


Area Broadcasting


The system can randomly separate a few network tools into various areas to play specified audio programs or send out news to any kind of assigned area. The volume of each tool can be from another location changed.


Real-time Broadcasting


The system can relay and record radio programs or various other exterior audio resources in real-time, and at the exact same time relayed them in sync.


Smoke Alarm Combination


The system can be integrated with the smoke alarm system for control. When a fire alarm signal is activated, IP PA System it immediately turns on the emergency program function and supports surrounding floor alarm systems. It likewise permits hands-on emergency broadcasting by clicking a solitary button.


SIP Phone Assimilation


The system can be incorporated with SIP servers, enabling live speech of voice broadcasting by means of SIP phones to send statements anytime and anywhere.


CCTV Assimilation


The digital gadgets such as IP POE Audio speakers adopts the global standard ONVIF protocol, which enables their voices to be broadcast using VMS platforms. The terminals can also be integrated with CCTV systems for synchronized program.


Main Products



Sound Monitoring Software XC-9000


B/S architecture, supports cross-platform applications.
Covers typical broadcasting system functions, enabling partition management.
Unified management of terminals within the system, watching job status, and batch quantity change, and so on.
Supports building multi-level server architectures, releasing administration according to individual geographical regions.
Supplies SDK growth bundles for additional development and assimilation with various other system platforms.


Network Paging Console XC-9038N


Power: DC12V/1.5 A.
Show: 4-inch touchscreen, resolution 480 * 480.
Interaction Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Regularity Action: 100Hz~ 16KHz.
Operating Temperature level: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Paging Console XC-9037N


Power Supply: DC12V/1.5 A.
Display: 4-inch touchscreen, resolution 480 * 480.
Interaction Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Regularity Action: 100Hz~ 16KHz.
Operating Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Horn Audio Speaker GEN-6391A03


Power Supply: DC24V/2.7 A or POE.
Communication Procedure: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Feedback: 100Hz~ 18KHz.
Intercom: Supported, Built-in Microphone.
Running Temperature level: -20~ 50 ℃.
Dimensions: 283.1 * 224.3 * 269mm.


Network Ceiling Audio Speaker GEN-6211A03


Power Supply: DC 24V/1A or POE.
Communication Methods: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Feedback: 100Hz~ 18KHz.
Operating Temperature: -20 to 50 ° C.
Capacities: φ213 x 165mm.


Network Wall Mount Speaker GEN-6011A03


Power Supply: DC24V/1A or POE.
Interaction Protocol: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Action: 100Hz~ 18KHz.
Running Temperature level: -20~ 50 ℃.
Measurements: 193x151.5 x292mm.


Network Column Speaker GEN-6191A03




Power Supply: DC24V/1A or POE.
Interaction Procedure: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 90dB.
Frequency Action: 45Hz~ 18KHz.
Operating Temperature level: -10~ 55 ℃.
Measurements: 296x140x130mm.


Network Audio Bridge GEN-3101A01


Power Supply: POE.
Interaction Method: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 85dB.
Regularity Reaction: 50Hz~ 20KHz.
Running Temperature level: -10~ 55 ℃.
Measurements: 126x66x27mm.


Network Digital Amplifier XC-9508P


Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Communication Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Regularity Response: 60Hz~ 18KHz.
Operating Temperature: -10~ 50 ℃.
Measurements: 440x300x44mm.


Zone Combining Digital Amplifier NBS-2301


Power Supply : AC 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Communication Procedure : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Ratio :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Regularity Reaction :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Running Temperature level :.
10 ℃~ +50 ℃ (14 ℉~ 122 ℉)
Measurements : 483x430x88mm.


IP Interface System NAC-5003


Power Supply: AC100V~ 240V, 50/60Hz.
Interaction Method: TCP/IP, UDP.
Interfaces: 1 Ethernet port, 32 alarm inputs, 8 alarm outcomes.
Running Temperature: -10~ 50 ℃.
Dimensions: 483x259x44mm.


Service For Institution





Adaptable Zoning Program:


The totally network terminals can recognize versatile zoning options, permitting transmitting notices to different areas or private terminals ( gadgets).


School Bell System:


It provides college bell system at the beginning/ending of the class - SPON Communications. Multiple scenarios can be created, including various arranged broadcast jobs according to summer/winter schedule


Smoke Alarm Integration


It sustains integration with emergency alarm systems, permitting fire alarm signals to be integrated right into the PA system.


Class Audio Boosting


Terminals support daily applications in class scenes. They can be connected to projectors or interactive white boards for audio boosting.


Ip SpeakerIp Paging System

Smart Street Lamp/Security Pole



Assistance SIP Protocol:


Integrated SIP method for seamless assimilation with network communication systems.


VMS Operatings Systems Assimilation:


Integrated ONVIF protocol for assimilation with VMS platforms.


Third-Party Assimilation:


Integrated In HTTP API for assimilation with 3rd party platforms.


Voice Alarm Causing:


Constructed in alarm system input user interface for setting off voice alarm systems with video cameras.


Remedy For Hotel



Zone Control by Flooring:


The system provides full network setups, dividing areas depending on various floorings and control over each zone independently.


Smoke Alarm Integration:


The system can be incorporated with emergency alarm system, enabling assimilation of smoke alarm signals into the broadcasting system.


Scheduled Broadcasting:


It supports programmable set up broadcasting, allowing versatile setups according to various demands.


Emergency Broadcasting:


It sustains emergency situation broadcasting for the whole area, allowing one-click emergency interaction.


Service For Factory



Zone Broadcasting:


It enables relaying to any kind of area, ensuring no interference in between various locations.


Alarm system Triggering:


Terminals have numerous type of interfaces, allowing to activate alarm systems when gotten in touch with electronic cameras.


All Network Devices:


Release of completely network tools significantly lowers the trouble of running such as examining gadgets on hazardous websites, and therefore securing people and building.


The deployment of all network devices greatly reduces the trouble of procedure and upkeep management


Integrated SIP Phones:


The system can be incorporated with SIP phone and program alerts utilizing SIP phones any time and anywhere. Two-way audio talkback between SIP phones and IP POE Audio speakers makes it simple for inspecting devices being in workplace or other workplaces.


The XC-9000 system is a fully electronic network PA system based on the TCP/IP protocol. By leveraging the TCP/IP method, the system makes certain the proper and reliable transmission of all data packages. The system sustains different kinds of audio resources for sending alerts like online speech and BGM playback. In addition, the system gives varied functions of supporting numerous broadcasting functions such as scheduled broadcasting, zoned broadcasting, and emergency situation broadcasting.


The system can be integrated with the fire alarm system for control.

Report this page